ID Category Severity Type Date Submitted Last Update
0001775 [1003.1(2016/18)/Issue7+TC2] Base Definitions and Headers Editorial Enhancement Request 2023-09-13 19:56 2023-12-07 14:08
Reporter enh View Status public  
Assigned To
Priority normal Resolution Accepted  
Status Applied  
Name Elliott Hughes
Organization Google
User Reference
Section <signal.h> siginfo_t si_addr description
Page Number 336
Line Number 11382
Interp Status ---
Final Accepted Text
Summary 0001775: si_addr description confusingly over-specific
Description the description of siginfo_t::si_addr is currently:
```
void *si_addr Address of faulting instruction.
```
which is over-specific to SIGILL.
Desired Action something like this seems like it would be more accurate/less confusing:
```
void *si_addr Address that caused fault.
```
Tags applied_after_i8d3, tc3-2008
Attached Files

- Relationships

There are no notes attached to this issue.

- Issue History
Date Modified Username Field Change
2023-09-13 19:56 enh New Issue
2023-09-13 19:56 enh Name => Elliott Hughes
2023-09-13 19:56 enh Organization => Google
2023-09-13 19:56 enh Section => <signal.h> siginfo_t si_addr description
2023-09-13 19:56 enh Page Number => 666
2023-09-13 19:56 enh Line Number => 666
2023-09-13 20:46 Don Cragun Page Number 666 => 336
2023-09-13 20:46 Don Cragun Line Number 666 => 11382
2023-09-13 20:46 Don Cragun Interp Status => ---
2023-11-16 17:00 Don Cragun Status New => Resolved
2023-11-16 17:00 Don Cragun Resolution Open => Accepted
2023-11-16 17:01 Don Cragun Tag Attached: tc3-2008
2023-12-07 14:08 geoffclare Status Resolved => Applied
2023-12-07 14:08 geoffclare Tag Attached: applied_after_i8d3